triovr.blogg.se

Plastic preform
Plastic preform






plastic preform

Plastics preforms come in many shapes and sizes, and vary from transparent to effectively opaque. The length of the preform must be at least 50-mm. The side-loading Adjustable Reflectance Preform Holder accepts translucent and opaque preforms from a minimum diameter of15-mm to a maximum diameter of 40-mm. HunterLab sphere instruments have powerful pulsed xenon lamp sources, and measurements are generally immune to ambient light. If the preform sticks above the transmission compartment, just draw the door close to the preform and take a measurement with the tube sticking out of the top. Any preform higher than about 4 inches will stick up through the top of the transmission compartment. The top-loading Adjustable Transmission Preform Holder accepts transparent preforms from a minimum diameter of 10-mm to a maximum diameter of 40-mm. The averaging of multiple readings with rotation is recommended to minimize measurement variation due to preform replacement between readings, as well as variation in the color uniformity and wall thickness of the preform. For each measurement, average 3 - 4 readings with rotation between each reading.Standardize normally in the SAV mode (instruments must be ordered with this option) for either RSIN reflectance and TTRAN transmission as appropiate.

#PLASTIC PREFORM PRO#

Two types of HunterLab universal preform holders:ġ- Adjustable Transmission Preform Holder for Clear Preformsįor ColorQuest XT, ColorQuest XE, UltraScan VIS and UltraScan PROĢ- Adjustable Reflectance Preform Holder for Opaque Preformsįor ColorQuest XE, UltraScan VIS and UltraScan PRO The purpose of a preform holder is to allow consistent placement of the highly curved preform at the measurement port so that a repeatable measurement can be achieved.

plastic preform

Color measurements of bottle cut-outs are used to verify lot-to-lot consistency and conformance to specification.Īdjustable Preform Holders for ColorQuest and UltraScan.Haze measurements of bottle cut-outs are used to verify that internal scattering is minimal from lot-to-lot.Spectral measurements in the 360 - 390nm range on an UltraScan PRO and UltraScan VIS can be used to verify the presence of a UV absorber for food grade bottle cut-outs (can also be done on preforms with caution).

plastic preform

  • Preform color measurements can be used to verify lot-to-lot consistency, predict final blown bottle color from the preform color and get into target range when switching over a line to a new color.







  • Plastic preform